ATEX HVAC
HVAC air handling units provide air renovation, air pressurization and air control temperature. They are strong and suitable for explosion proof areas and industrial environments.
- Long lifetime.
- Withstand extreme weather conditions.
- Easy installation and maintenance.
- Withstand power supply fluctuations.
- Double fan.
- Adaptation to particular requirements.
- Increased efficiency.
- Reduced noise level.
- Suitable for zone 1 and 2.
- Certified safety.
CLB Series
Features
- 3~ (380-420 50Hz / 440-480 60Hz) without neutral.
- Other voltages available on request.
- Standard: -20ºC…+50ºC.
- Low temperatures version: -40ºC…+50ºC.
- High temperatures version: -20ºC…+60ºC.
- Available powers from 3,8 KW to 73,6 KW.
- Vertical structure connected by flexible air ducts.
- Weather resistant stainless steel.
- Double fan to ensure the air pressurization.
- Fan running manual selection.
- Automatic rotation.
- Automatic start for the standby fan.
- “Both fans running” signal.
- Air pressure detector.
- ATEX certified filters, easy extraction and cleaning.
- High performance semi-hermetic compressor.
- Refrigerant pressure gauges.
- Adjustable control thermostat with digital display.
- Control panel with monitoring and controls.
- Input and output control signals.
- Air renovations/pressurization and thermal loads calculations.
- Dimensional drawings.
- Electrical schematics.
- User manual, installation, security and maintenance.
Structure:
- AISI-316 stainless steel.
- Structure completely painted.
- Horizontal structure version.
- External air conditioning with remote control panel.
- Units on two parts, split type.
- Custom equipment installation as required.
Air circuit:
- Elastic direct drive transmission.
- High pressure fan with direct drive.
- Other constructive versions available on request.
- Chemical filter and prefilter included.
- Air dampers with Ex electric actuator.
- Air dampers with Ex pneumatic actuator.
- Air fire dampers.
- Air flow thermal detector.
- “Low air flow rate (%)” output signal.
Cooling system:
- Cylinder head partialization.
- Air exchangers with anticorrosive treatment: Lacquered, Blygold, Heresite.
- Copper exchangers.
- Stainless steel exchangers.
- Liquid receiver.
- Liqud separator with heat exchange.
- Oil separator with return to the compressor.
- Water condensation system with constant pressure valve.
- Heat recovery.
Heating:
- Steam exchanger, control valve and electro-pneumatic actuator.
- Electrical resistors.
Control:
- Custom control panel.
- Customized input and output signals.